As demand for digital infrastructure to support cloud technologies and artificial intelligence continues to grow, data centers are becoming a common part of both urban and rural settings. With that growth, communities are naturally curious about how these new neighbors will fit in. One topic that often comes up is sound — specifically, how much noise such facilities may produce.

The answer is nuanced, as ambient data center sound is strongly influenced by the facility’s design. Generally speaking, modern data centers do produce some external sound, but the levels are typically comparable to — and often lower than — many everyday commercial and industrial facilities already operating within communities.

Understanding Where Data Center Noise Comes From

It’s worth acknowledging that data centers, like any active facility, do produce some ambient sound. The primary sources of external sound are typically the cooling equipment, such as chillers, air handling units, and rooftop fans. Backup generators may also produce brief sound during scheduled testing, as do service vehicles, employee traffic, and delivery trucks. The servers themselves also produce sound, but it is rarely audible beyond the building envelope, according to a Microsoft fact sheet.

One characteristic worth understanding is the nature of the sound rather than its volume. While traffic or construction noise tends to be intermittent, data center cooling systems run continuously, producing a steady, low-frequency background hum. Some residents may notice this consistency, particularly at night when other ambient sounds drop off — a characteristic that thoughtful design can readily address.

How Data Centers Compare to Everyday Ambient Noise

When put into context, the sound levels surrounding a data center are not so unusual. The U.S. Environmental Protection Agency identifies outdoor noise levels around 55 decibels (dB) as the generally accepted threshold for avoiding widespread community annoyance in residential areas. Many state and local laws use this as a baseline for their own property line compliance ordinances.

For comparison, here are some other common noise levels.

Moderate rainfall[1] 50 dB
Normal conversation1 60 dB
Freeway traffic[2] 70 dB
Vacuum cleaners1 70 dB
A noisy restaurant1 80 dB
Heavy traffic[3] 85 dB
Motorcycles1 100 dB
Sporting events1 110 dB
A crying baby 110 dB
Fireworks1 140 dB

 

For a more apples-to-apples comparison, other industrial facilities must follow long-established EPA guidelines requiring noise levels not to exceed an average of 70 dB over any 24-hour period, measured at the property line for community impact. As such, most fulfillment centers, distribution centers, factories, foundries, truck lots, ports, and other industrial facilities adhere to those guidelines by employing noise mitigation techniques and equipment, or by ensuring the property line is far enough from the source to allow noise to fade below acceptable levels.

By contrast, a well-designed data center engineered to meet local noise limits at the property line will measure around 50-60 dB at the property line, which is in line with or below the standards of other commercial developments.

The conversation around data center sound often centers more on consistency than on volume. A busy restaurant or retail environment tends to have fluctuating, intermittent sound from customer traffic, deliveries, or cycling equipment. Computer servers generate heat, so cooling systems run continuously. With thoughtful design, however, this consistent operation can be managed so that residents experience a steady, unobtrusive background — not unlike the gentle hum of a refrigerator or HVAC system.

[1] “Decibel Chart: All You Need to Know,” MD Hearing, https://mdhearingaid.com/blog/decibel-chart

[2] “Common Environmental Noise Levels,” CHC Hearing, https://chchearing.org/common-environmental-noise-levels

[3] “Common Environmental Noise Levels,” CHC Hearing, https://chchearing.org/common-environmental-noise-levels

Managing Noise Concerns with the Right Approach

One of the most encouraging and often overlooked facts about data center sound is that it can be managed effectively. Because the primary sources of sound are mechanical and predictable, architects and developers can address them through careful design and engineering — in a more controlled and proactive way than is possible with many other types of commercial or transportation infrastructure.

The Environmental and Energy Study Institute discusses a number of common noise mitigation strategies that developers can incorporate, including:

  • Strategic site layouts/setbacks to put maximum distance between the facility and communities
  • Acoustic barriers, enclosures, compressor sound blankets, sound curtains, and sound walls
  • Planting tall, thick varieties of trees between data centers and residential neighbors
  • Including noise generation as a selection metric for equipment
  • Optimizing equipment placement to reduce directional noise
  • Installing mufflers and attenuation systems on backup generators
  • Leveraging more advanced cooling technologies, such as liquid cooling, immersion cooling, or quieter fan systems

This last point is essential because much of the research on data center noise comes from years of data collected in communities with air-cooled data centers, which are traditionally much louder than modern liquid-cooled systems.

Finding a Balance Between Growth and Community Expectations

Digital infrastructure will continue to expand, meaning data centers will remain at the core of local economic development strategies for the foreseeable future. As such, it’s essential that community leaders and data center stakeholders find ways to make these facilities tenable for the communities they will exist in. Addressing community concerns around noise is a critical part of that process.

There is good news, however. Noise generation by data centers and its impact on communities is much better understood than it was even 10 years ago. This understanding also makes it much more manageable. With intentional design and modern engineering, data centers can coexist with surrounding communities just as well as any other commercial or industrial development.

For experienced developers, the goal must be to not simply meet requirements, but to anticipate the concerns of local communities and preemptively address them, ensuring that essential digital infrastructure supports both the economic growth and the quality of life of community residents.